{"product_id":"automated-cold-plate-laser-welding-leak-testing-line","title":"Automated Cold Plate Laser Welding \u0026 Helium Leak-Testing Line","description":"\u003cstyle\u003e.lcx-existing-visual{margin:0 0 30px}.lcx-existing-visual img{display:block;width:100%;height:auto;max-width:1200px;aspect-ratio:16\/9;object-fit:cover;border-radius:12px}.lcx-existing-visual figcaption{font-size:.86rem;color:#526b7d;margin-top:12px;line-height:1.6}.lcx-cross{margin:32px 0;padding:25px;background:#edf6fb;border:1px solid #c8dfe9;border-radius:12px;color:#17374d}.lcx-cross h2{font-size:1.4rem;line-height:1.4;margin:0 0 18px}.lcx-cross ul{padding-left:22px}.lcx-cross li{margin:10px 0;line-height:1.65}.lcx-cross a{color:#006ca8;text-decoration:underline}\u003c\/style\u003e\u003cfigure class=\"lcx-existing-visual\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0994\/2699\/2444\/files\/aogeo-liquid-cooling-p04-equipment-1600.webp?v=1793025811\" alt=\"Integrated cold plate welding cell, helium test chamber and pallet transfer\" width=\"1600\" height=\"900\" loading=\"eager\"\u003e\u003cfigcaption\u003eWelding and helium inspection remain distinct stations in an integrated route.\u003c\/figcaption\u003e\u003c\/figure\u003e\u003cstyle\u003e.lc-content{--lc-ink:#17394e;--lc-blue:#086d9f;--lc-line:#cfdfeb;--lc-soft:#eff6fb;color:var(--lc-ink);font:inherit;line-height:1.75;max-width:1220px;margin-inline:auto;overflow-wrap:anywhere}\n.lc-content *{box-sizing:border-box}.lc-content p{margin:0 0 1.1em}.lc-content a{color:var(--lc-blue);text-underline-offset:4px}.lc-content a:hover{text-decoration-thickness:2px}.lc-content a:focus-visible,.lc-content summary:focus-visible{outline:3px solid #087eae;outline-offset:5px}\n.lc-content h2{font-size:clamp(1.5rem,2.4vw,2.1rem);line-height:1.3;margin:2.2em 0 .75em;color:#12394e;scroll-margin-top:180px}.lc-content h3{font-size:1.15rem;line-height:1.45;margin:1.3em 0 .55em;color:#17394e}.lc-content ul,.lc-content ol{padding-left:1.4em}.lc-content li+li{margin-top:.45em}\n.lc-content .lc-hero{padding:clamp(22px,4vw,52px);background:linear-gradient(120deg,#092b43,#075a7f);color:#fff;border-radius:14px;margin-bottom:22px}.lc-content .lc-hero h2,.lc-content .lc-hero h3,.lc-content .lc-hero a{color:#fff}.lc-content .lc-hero p:last-child{margin-bottom:0}.lc-content .lc-eyebrow{font-size:.82rem;text-transform:uppercase;font-weight:700;letter-spacing:.12em;color:#0878ad}.lc-content .lc-hero .lc-eyebrow{color:#a9ddf5}\n.lc-content .lc-kicker{font-size:.82rem;font-weight:700;letter-spacing:.1em;text-transform:uppercase}.lc-content .lc-lead{font-size:clamp(1.05rem,1.4vw,1.25rem)}.lc-content .lc-section{scroll-margin-top:180px}.lc-content .lc-nav{display:flex;gap:8px;flex-wrap:wrap;padding:12px;border:1px solid var(--lc-line);border-radius:10px;background:#fff;margin:20px 0}.lc-content .lc-pillar\u003e.lc-nav{position:sticky;top:var(--header-height,90px);z-index:6}.lc-content .lc-nav a{display:inline-flex;align-items:center;min-height:44px;padding:8px 14px;background:var(--lc-soft);border-radius:7px;text-decoration:none;font-weight:600}\n.lc-content .lc-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,260px),1fr));gap:18px;align-items:start}.lc-content .lc-card{background:#fff;border:1px solid var(--lc-line);border-top:3px solid #0879ab;border-radius:10px;padding:24px;min-width:0}.lc-content .lc-card h3{margin-top:0}.lc-content .lc-card p:last-child{margin-bottom:0}\n.lc-content .lc-callout,.lc-content .lc-note{padding:20px 24px;background:var(--lc-soft);border-left:4px solid #087eae;border-radius:0 9px 9px 0;margin:24px 0}.lc-content .lc-cta{padding:26px;background:#e8f4fa;border:1px solid #bddbe9;border-radius:12px;margin-top:32px}.lc-content .lc-cta a,.lc-content .lc-button{display:inline-flex;align-items:center;min-height:46px;padding:10px 18px;margin:5px 8px 5px 0;background:#086d9f;color:#fff;border-radius:7px;text-decoration:none;font-weight:600}\n.lc-content .lc-table-wrap{width:100%;overflow-x:auto;margin:20px 0;border:1px solid var(--lc-line);border-radius:9px}.lc-content table{width:100%;border-collapse:collapse;font-size:.95rem;margin:0}.lc-content th{background:#e8f2f8;text-align:left;color:#17394e}.lc-content th,.lc-content td{padding:14px 16px;border-bottom:1px solid var(--lc-line);vertical-align:top;min-width:145px}.lc-content tr:last-child td{border-bottom:0}\n.lc-content details{align-self:start;border:1px solid #bed6e6;background:#f8fbfd;border-radius:9px;margin:12px 0;padding:0 20px}.lc-content summary{cursor:pointer;min-height:58px;display:list-item;padding:16px 6px;font-weight:700;color:#075c88;list-style-position:inside}.lc-content summary::marker{color:#087eae;font-size:1.1em}.lc-content details[open] summary{border-bottom:1px solid var(--lc-line);margin-bottom:16px}.lc-content details\u003ep:last-child{padding-bottom:12px}.lc-content .lc-source{font-size:.9rem;color:#4c6576}\n.lc-content .lc-flow{display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,210px),1fr));gap:12px;list-style:none;padding:0;counter-reset:lc-step}.lc-content .lc-flow\u003eli{counter-increment:lc-step;border:1px solid var(--lc-line);background:var(--lc-soft);border-radius:9px;padding:20px;margin:0}.lc-content .lc-flow\u003eli::before{content:counter(lc-step,decimal-leading-zero);display:block;font-weight:700;color:#0879ab;margin-bottom:7px}.lc-content .lc-flow strong{display:block}\n.lc-content summary .lc-expand{display:inline-flex;align-items:center;margin-inline-start:.75rem;padding:.22em .7em;border:1px solid #b8d4e4;border-radius:999px;background:#e9f3fa;color:#075c88;font-size:.78em;font-weight:700;line-height:1.4;white-space:nowrap;vertical-align:middle}\n.lc-content summary .lc-expand-open{display:none}.lc-content details[open]\u003esummary .lc-expand-closed{display:none}.lc-content details[open]\u003esummary .lc-expand-open{display:inline}.lc-content details[open]\u003esummary .lc-expand{border-color:#086d9f;background:#086d9f;color:#fff}\n@media(max-width:640px){.lc-content{font-size:16px}.lc-content .lc-hero{border-radius:9px}.lc-content .lc-card{padding:18px}.lc-content .lc-nav{flex-wrap:nowrap;overflow-x:auto;max-width:100%}.lc-content .lc-nav a{flex:0 0 auto}.lc-content th,.lc-content td{padding:11px 12px;min-width:138px}.lc-content summary{min-height:52px}.lc-content .lc-cta{padding:20px}.lc-content h2{scroll-margin-top:155px}}\u003c\/style\u003e\u003cdiv class=\"lc-content\" lang=\"en\"\u003e\u003cdiv class=\"lc-page lc-product\"\u003e\u003cdiv class=\"lc-hero\"\u003e\u003cp class=\"lc-kicker\"\u003eLIQUID COOLING MANUFACTURING EQUIPMENT\u003c\/p\u003e\u003cp class=\"lc-lead\"\u003eConnect cold plate laser welding, helium leakage verification and traceable material flow in one engineered line. Begin with the component family and acceptance route, then define station responsibilities, buffers, data interfaces and rejection handling.\u003c\/p\u003e\u003cdiv class=\"lc-actions\"\u003e\u003ca class=\"lc-button\" href=\"\/pages\/request-a-quote\"\u003eSend drawings for a quotation\u003c\/a\u003e\u003ca href=\"\/pages\/sample-testing-process-validation\"\u003ePlan sample validation\u003c\/a\u003e\u003c\/div\u003e\u003c\/div\u003e\u003csection class=\"lc-section\" id=\"line-scope\"\u003e\u003ch2\u003eAn integrated line is more than a faster welding station\u003c\/h2\u003e\u003cp\u003eThe \u003ca href=\"\/products\/copper-cold-plate-laser-welding-system\"\u003ecopper cold plate welding platform\u003c\/a\u003e addresses the joining operation. This line adds the coordination needed to move identified parts through the selected preparation, welding and testing route. It can also interface with a \u003ca href=\"\/products\/liquid-cooling-manifold-tube-laser-welding-cell\"\u003emanifold and tube-joint cell\u003c\/a\u003e where the project includes those assemblies. Define the supported product mix and changeover method rather than treating every part as one recipe.\u003c\/p\u003e\u003cp\u003eAgree the incoming condition, output condition and responsibility for each boundary: loading, fixture handling, cleaning, process gases, test connections, code reading and factory data exchange. Final channel cleaning and separate structural or thermal tests remain explicit tasks wherever they sit in the overall manufacturing plan.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"lc-section\" id=\"stations\"\u003e\u003ch2\u003eBuild the station map from the quality route\u003c\/h2\u003e\u003cdiv class=\"lc-table-wrap\"\u003e\u003ctable class=\"lc-table\"\u003e\u003ccaption\u003eExample station functions to configure, not a fixed universal sequence\u003c\/caption\u003e\u003cthead\u003e\u003ctr\u003e\u003cth scope=\"col\"\u003eFunction\u003c\/th\u003e\u003cth scope=\"col\"\u003ePlanning focus\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth scope=\"row\"\u003eIdentification and loading\u003c\/th\u003e\u003ctd\u003eCorrect part, fixture, recipe and incoming disposition\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\"\u003ePreparation and positioning\u003c\/th\u003e\u003ctd\u003eRequired cleanliness, datums, fit-up and access\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\"\u003eLaser welding\u003c\/th\u003e\u003ctd\u003eSelected beam\/source configuration, trajectory and process record\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\"\u003eTest preparation\u003c\/th\u003e\u003ctd\u003eDefined seals, tracer-gas handling and readiness checks\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\"\u003eOverall helium testing\u003c\/th\u003e\u003ctd\u003eSpecified method and acceptance conditions\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\"\u003eLocalization or rework routing\u003c\/th\u003e\u003ctd\u003eAuthorized handling of indications and repeat tests\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth scope=\"row\"\u003eMarking and release\u003c\/th\u003e\u003ctd\u003eIdentity, result association and final disposition\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003cp\u003eNot every project needs every station in this order. Marking may be earlier, cleaning may require separate equipment, and localization may be an offline rework task. The line design should show these decisions visibly so that quotation scope matches the real factory route.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"lc-section\" id=\"helium-modules\"\u003e\u003ch2\u003eDefine the helium boundary and its supporting modules\u003c\/h2\u003e\u003cp\u003eA \u003ca href=\"\/products\/cold-plate-vacuum-chamber-helium-leak-test-system\"\u003evacuum chamber station\u003c\/a\u003e can provide the defined overall leakage decision. A \u003ca href=\"\/products\/liquid-cooling-manifold-helium-sniffer-leak-test-station\"\u003esniffer station\u003c\/a\u003e can support accessible-joint localization. Tracer-gas filling, controlled discharge, recovery and concentration management are configured as modules when included in the project, with calibration and background checks integrated into the quality plan.\u003c\/p\u003e\u003cp\u003eGas handling follows the equipment design and factory safety plan. Define concentration verification, permitted part pressure differential and the test sequence with the responsible engineers. Do not compare line offers using detector sensitivity alone: fixtures, measurement path, cycle conditions and the agreed acceptance demonstration determine system capability.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"lc-section\" id=\"throughput-data\"\u003e\u003ch2\u003eMake cycle and data definitions comparable\u003c\/h2\u003e\u003cp\u003eSeparate the customer's required output from individual operation times, changeover, scheduled checks and recovery after an interrupted cycle. Identify the likely constraint station and the buffer or routing needed to prevent ambiguous part status. A nominal laser travel speed is not a line production commitment.\u003c\/p\u003e\u003cp\u003eDefine the minimum record for each part: identity, recipe and fixture version, applicable process result, helium-test conditions and disposition. Specify what happens when a code cannot be read, a record cannot be sent, or a test is interrupted. Factory-system connections and retention responsibilities belong in the interface document.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"lc-section\" id=\"acceptance\"\u003e\u003ch2\u003eAgree the commissioning evidence before ordering\u003c\/h2\u003e\u003cp\u003ePrepare representative product variants and a test matrix covering normal production, changeover, rejected parts and restart behavior. Machine FAT\/SAT and component qualification need related but distinct evidence. Use \u003ca href=\"\/blogs\/resources\/cold-plate-laser-welding-rfq-checklist\"\u003ethe RFQ checklist\u003c\/a\u003e, \u003ca href=\"\/blogs\/resources\/cold-plate-helium-vacuum-chamber-vs-sniffer\"\u003ethe helium-method guide\u003c\/a\u003e and \u003ca href=\"\/blogs\/resources\/cold-plate-helium-leak-test-acceptance-conditions\"\u003ethe acceptance-conditions guide\u003c\/a\u003e to make the deliverables testable.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"lc-section\" id=\"faq\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003cdetails class=\"lc-faq\"\u003e\u003csummary\u003eDoes the line need both chamber and sniffer stations?\u003cspan class=\"lc-expand\" aria-hidden=\"true\"\u003e\u003cspan class=\"lc-expand-closed\"\u003eView answer\u003c\/span\u003e\u003cspan class=\"lc-expand-open\"\u003eHide answer\u003c\/span\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"lc-faq-content\"\u003e\u003cp\u003eOnly when the quality and routing plan calls for both tasks. Localization can be offline; the selected overall acceptance method must still be qualified.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails class=\"lc-faq\"\u003e\u003csummary\u003eCan a quoted welding speed define the whole line output?\u003cspan class=\"lc-expand\" aria-hidden=\"true\"\u003e\u003cspan class=\"lc-expand-closed\"\u003eView answer\u003c\/span\u003e\u003cspan class=\"lc-expand-open\"\u003eHide answer\u003c\/span\u003e\u003c\/span\u003e\u003c\/summary\u003e\u003cdiv class=\"lc-faq-content\"\u003e\u003cp\u003eNo. Compare the complete operating cycle, product mix, checks, changeover and agreed availability assumptions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/laser-solutions-liquid-cooling\"\u003eExplore the liquid cooling manufacturing solution\u003c\/a\u003e\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003csection class=\"lcx-cross\" data-lcx-existing=\"P04\"\u003e\u003ch2\u003eRelated processes, equipment and validation guides\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/pages\/laser-solutions-liquid-cooling\"\u003eLiquid Cooling Manufacturing: Laser Processing, Helium Testing \u0026amp; Automation ↗\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/pages\/liquid-cooling-welding-leak-testing-automation\"\u003eAutomated Welding and Leak-Testing Lines for Liquid Cooling Components ↗\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/pages\/cold-plate-laser-welding\"\u003eCold Plate Laser Welding: From Joint Design to Qualified Production ↗\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/pages\/liquid-cooling-helium-leak-testing\"\u003eHelium Leak Testing for Liquid Cooling Components ↗\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/pages\/liquid-cooling-laser-marking-traceability\"\u003eLaser Marking and Traceability for Liquid Cooling Components ↗\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/pages\/liquid-cooling-process-qualification\"\u003eProcess Qualification and Acceptance for Liquid Cooling Components ↗\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/blogs\/resources\/automated-cold-plate-welding-leak-test-line-planning\"\u003eCold Plate Welding and Helium Test Lines: Find the Real Production Bottleneck ↗\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/blogs\/resources\/gantry-vs-robotic-cold-plate-manifold-laser-welding\"\u003eGantry vs Robot for Cold Plates and Manifolds: A Part-Access Decision Checklist ↗\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/blogs\/resources\/cold-plate-weld-monitoring-vs-leak-testing\"\u003eInline Weld Monitoring vs Final Leak Testing for Cold Plates ↗\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/section\u003e","brand":"AOGEO","offers":[{"title":"Default Title","offer_id":67782109102396,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0994\/2699\/2444\/files\/aogeo-liquid-cooling-p04-equipment-1600.webp?v=1793025811","url":"https:\/\/aogeolaser.com\/products\/automated-cold-plate-laser-welding-leak-testing-line","provider":"上海奥剑激光设备有限公司","version":"1.0","type":"link"}